Mindray Patient Monitor , Multifunctional Patient Monitoring Device
hot selling high small handheld handheld patient monitor
Quick Detail:
PM50 is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care.
Description:
*Compact and portable, easy to use
*With Integrative SpO2 Probe
*Double working modes,monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
*NIBP and SpO2 can be monitored for a long time
*NIBP and SpO2 data record for large capacity
*With friendly user interface, the user can see list menu and review measure results
*The device can display low power information, alarm information, error information and time information richly
*Parameter alarm function is optional
*Patient information can be flexibly set
*Case management function.PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions
Applications:
can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Specifications:
*NIBP
Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range:
ADULT: SYS: 40mmHg270mmHg
MAP:20mmHg235mmHg
DIA: 10mmHg215mmHg
PEDIATRIC: SYS: 40mmHg200mmHg
MAP: 20mmHg165mmHg
DIA: 10mmHg150mmHg
NEONATAL: SYS: 40mmHg135mmHg
MAP: 20mmHg110mmHg
DIA: 10mmHg100mmHg
Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP / DIA
*SPO2
Measure range: 0%100% (Resolution:1%)
Accuracy: 70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
*Pulse Rate
Measuring range:0bpm250bpm
Resolution:1bpm
Accuracy: ±2 bpm or ±2% (select larger)
*Display: 2.4" TFT colour LCD
*Power: DC 3V(Two "AA",1.5V Alkali Battery)
*Product safety type:Type BF applied part (Internally powered,defibrillation-proof)